Product Description
Dimensions: | 14 cm x 21 cm x 14 cm (5 in. x 7.5 in. x 5 in.) |
Material: | High impact ABS plastic enclosure |
Operating Temperature: | -29°C to +49°C (-20°F to +120°F) For UL Certificated installations, 0°C to +49°C (+32°F to +120°F) |
Radio Frequency Interference (RFI) Immunity: | No alarm or setup on critical frequencies in the range from 26 MHz to 950 MHz at 50 V/m. |
DS794ZE: | Complies with Environmental Class II (EN50130-5) |
Height: | 5 m (15 ft.) maximum |
Location: | Surface or corner |
Current Draw: | 18 mA at 12 VDC 25 mA at 12 VDC (DS794ZE) |
Voltage (Input): | 6 VDC to 15 VDC ZX794Z: Power comes from two-wire Zonex Bus. <0.5 mA nominal, 2 mA in alarm with LEDs enabled. Do not leave Walk Test LEDs enabled. |
Alarm: | ZX794Z: Signal through POPIT data bus. |
DS794ZE-FRA: Form C Contacts rated at 3.0 W, 125 mA at 28 VDC for resistive loads protected by a 4.7 Ω resistor in the common C leg. | |
Tamper: | Normally-closed (with cover in place). Contacts rated at 28 VDC, 125 mA maximum. |
ZX794Z: Signal through POPIT data bus. Signaled as Missing. | |
Trouble: | Solid state output, shorts to negative when activated. Maximum current load is 25 mA. |
ZX794Z: Signal through POPIT data bus. | |
Sonalert® is a registered trademark of Mallory Sonalert® Products, Inc. |
Leave a Reply